ZHCSGS4A August 2017 – February 2020 ADS114S06B , ADS114S08B
PRODUCTION DATA.
请参考 PDF 数据表获取器件具体的封装图。
If the ADC connection leads are in close proximity to industrial motors and conductors, coupling of 50-Hz and
60-Hz power line frequencies can occur. The coupled noise interferes with the signal voltage, and can lead to inaccurate or unstable conversions. The digital filter provides enhanced rejection of power-line-coupled noise for data rates of 60 SPS and less. Program the filter to tradeoff data rate and conversion latency versus the desired level of line cycle rejection. Table 8 summarizes the ADC 50-Hz and 60-Hz line-cycle rejection based on ±1-Hz and ±2-Hz tolerance of power-line frequency. The best possible power-line rejection is provided by using an accurate ADC clock.
DATA RATE (SPS)(1) | DIGITAL FILTER LINE CYCLE REJECTION (dB) | |||
---|---|---|---|---|
50 Hz ± 1 Hz | 60 Hz ± 1 Hz | 50 Hz ± 2 Hz | 60 Hz ± 2 Hz | |
2.5 | –113.7 | –95.4 | –97.7 | –92.4 |
5 | –111.9 | –95.4 | –87.6 | –81.8 |
10 | –111.5 | –95.4 | –85.7 | –81.0 |
16.6 | –33.8 | –20.9 | –27.8 | –20.8 |
20 | –95.4 | –95.4 | –75.5 | –80.5 |
50 | –33.8 | –15.5 | –27.6 | –15.1 |
60 | –13.4 | –35.0 | –12.6 | –29.0 |