ZHCSQZ9A March 2022 – October 2022 ADS117L11
PRODUCTION DATA
Return to the Register Map Overview.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CS_MODE | ALV_FLAG | POR_FLAG | SPI_ERR | REG_ERR | ADC_ERR | MOD_FLAG | DRDY |
R-xb | R/W-1b | R/W-1b | R/W-0b | R/W-0b | R-xb | R-xb | R-xb |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | CS_MODE | R | xb | CS mode. 0b = 4-wire SPI operation
(CS is active) 1b =
3-wire SPI operation (CS is tied
low) |
6 | ALV_FLAG | R/W | 1b | Analog supply
low-voltage flag. 0b = No analog supply low-voltage condition from when flag last cleared 1b = Analog supply low-voltage condition detected |
5 | POR_FLAG | R/W | 1b | Power-on reset
(POR) flag. 0b = No reset from when the flag last cleared 1b = Device reset occurred |
4 | SPI_ERR | R/W | 0b | SPI communication
CRC error. 0b = No error 1b = SPI CRC error |
3 | REG_ERR | R/W | 0b | Register map CRC
error. 0b = No error 1b = Register map CRC error |
2 | ADC_ERR | R | xb | Internal ADC
error. 0b = No ADC error 1b = ADC error detected |
1 | MOD_FLAG | R | xb | Modulator
saturation flag. 0b = Modulator not saturated 1b = Modulator saturation detected during the conversion cycle |
0 | DRDY | R | xb | Data-ready bit. 0b = Data are not new 1b = Data are new |