ZHCSKD9 October 2019 ADS1235-Q1
PRODUCTION DATA.
Use the following procedure to calibrate using commands. The register-lock mode must be UNLOCK for all calibration commands. After power-on, make sure the reference voltage has stabilized before calibrating. Perform offset calibration before full-scale calibration.
DATA RATE
(SPS) |
FILTER MODE (1) | ||||
---|---|---|---|---|---|
FIR | SINC1 | SINC2 | SINC3 | SINC4 | |
2.5 | 6805 | 6801 | 7601 | 8401 | 9201 |
5 | 3405 | 3401 | 3801 | 4201 | 4601 |
10 | 1705 | 1701 | 1901 | 2101 | 2301 |
16.6 | — | 1021 | 1141 | 1261 | 1381 |
20 | 854.5 | 850.9 | 951.0 | 1051 | 1151 |
50 | — | 340.9 | 380.9 | 420.9 | 460.9 |
60 | — | 284.2 | 317.5 | 350.9 | 384.2 |
100 | — | 170.9 | 190.9 | 210.9 | 230.9 |
400 | — | 43.36 | 48.36 | 53.36 | 58.36 |
1200 | — | 15.02 | 16.69 | 18.36 | 20.02 |
2400 | — | 7.938 | 8.772 | 9.605 | 10.44 |
4800 | — | 4.397 | 4.813 | 5.230 | 5.647 |
7200 | — | 3.216 | 3.494 | 3.772 | 4.050 |