ZHCSMK4A september 2022 – july 2023 ADS131B26-Q1
PRODUCTION DATA
Other voltages in the BMS, such as the voltages before and after the main contactor, can be measured using ADC2A and ADC2B. The configuration of the ADCs and the selection of the resistor dividers follows the same guidelines as for the battery-pack voltage measurements using ADC3A and ADC3B.
In this example analog input V0A of ADC2A and analog input V0B of ADC2B are shown for voltage measurements. The negative multiplexer channels of ADC2A and ADC2B are using AGNDA and AGNDB, respectively.