ZHCSEJ3B June 2015 – April 2020 ADS131E08S
PRODUCTION DATA.
Setting CHnSET[2:0] = 011 sets the channel inputs to different device supply voltages. For channels 1, 2, 5, 6, 7, and 8 (MVDDP – MVDDN) is [0.5 × (AVDD – AVSS)]; for channels 3 and 4 (MVDDP – MVDDN) is
DVDD / 4. Set the gain to 1 to avoid saturating the PGA when measuring power supplies.