ZHCSAM3B December   2012  – April 2022 ADS54T01

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics
    6. 7.6  Electrical Characteristics
    7. 7.7  Electrical Characteristics
    8. 7.8  Electrical Characteristics
    9. 7.9  Electrical Characteristics
    10. 7.10 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Test Pattern Output
      2. 8.3.2  Clock Inputs
      3. 8.3.3  SNR and Clock Jitter
      4. 8.3.4  Analog Inputs
      5. 8.3.5  Over-Range Indication
      6. 8.3.6  Interleaving Correction
      7. 8.3.7  High-Resolution Output Data
      8. 8.3.8  Low-Resolution Output Data
      9. 8.3.9  Full Speed – 7 Bit
      10. 8.3.10 Decimated Low-Resolution Output Data
      11. 8.3.11 Multi Device Synchronization
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power-Down Modes
      2. 8.4.2 Feedback Mode: Burst Mode
      3. 8.4.3 Receive Mode: Decimation Filter
      4. 8.4.4 Manual Trigger Mode
      5. 8.4.5 Auto Trigger Mode
    5. 8.5 Programming
      1. 8.5.1 Device Initialization
      2. 8.5.2 Serial Register Write
      3. 8.5.3 Serial Register Readout
    6. 8.6 Register Maps
      1. 8.6.1 Serial Register Map
      2. 8.6.2 Description of Serial Interface Registers
  9. Power Supply Recommendations
  10. 10Device and Documentation Support
    1. 10.1 接收文档更新通知
    2. 10.2 支持资源
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Over-Range Indication

The ADS54T01 provides a fast over-range indication on the OVRA/B pins. The fast OVR is triggered if the input voltage exceeds the programmable overrange threshold and it gets presented after just 12 clock cycles enabling a quicker reaction to an overrange event. The OVR threshold can be configured using SPI register writes.

The input voltage level at which the overload is detected is referred to as the threshold and is programmable using the over-range threshold bits. The threshold at which fast OVR is triggered is (full-scale × [the decimal value of the FAST OVR THRESH bits] /16). After reset, the default value of the over-range threshold is set to 15 (decimal) which corresponds to a threshold of 0.56 dB below full scale (20 × log(15/16)).

Figure 8-6 OVR Detection Threshold