ZHCSFY7B January 2017 – December 2021 ADS58J64
PRODUCTION DATA
When auto trigger mode is enabled, the ADS58J64 starts transmission of low-resolution data. As soon as the low-resolution samples counter (LC) is finished, the ADS58J64 immediately begins transmitting the high-resolution output (H). The HRES flag can also be embedded in the JESD204B output data stream. The counter values can be updated until a new burst mode cycle starts with transmission of low-resolution samples. Any input on the trigger input pins is ignored.
An example of burst mode with an automatic trigger is shown in Figure 7-18.