ZHCSH75A September 2017 – December 2017 ADS7142
PRODUCTION DATA.
A write to this register aborts the channel scanning sequence. Once sequence is aborted using this register, it is recommended to read the DATA_BUFFER_STATUS register to know the number of entries filled in the data buffer or ACCUMULATOR_STATUS register to know number of accumulations finished before the abort.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | SEQ_ABORT |
R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | W-0b |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-1 | RESERVED | R | 0000000b | Reserved Bits. Read returns 0000000b |
0 | SEQ_ABORT | W | 0b | Setting this bit = 1 aborts the ongoing conversion and brings the BUSY/RDY pin low |