ZHCSH75A September 2017 – December 2017 ADS7142
PRODUCTION DATA.
Provides the status of sequence in device (Read Only).
This register is cleared at power-up, on receiving general call reset, on device reset or when SEQ_START bit in START_SEQUENCE register is set to 1.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
0 | 0 | 0 | 0 | 0 | SEQ_ERR_ST[1:0] | 0 | |
R-0b | R-0b | R-0b | R-0b | R-0b | R-00b | R-0b |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-3 | RESERVED | R | 00000b | Reserved bits. Reads return 00000b. |
2-1 | SEQ_ERR_ST[1:0] | R | 00b | Status of device sequence
00b = Auto Sequencing disabled, no error. 01b = Auto Sequencing enabled, no error. 10b = Not used 11b = Auto Sequencing enabled, device in error. |
0 | 0 | R | 0b | Reserved bit. Reads return 0. |