ZHCSIK6D November   2017  – June 2024 ADS8166 , ADS8167 , ADS8168

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Thermal Information
    4. 5.4 Recommended Operating Conditions
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Switching Characteristics
    8. 5.8 Timing Diagrams
    9. 5.9 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Analog Multiplexer
        1. 6.3.1.1 Multiplexer Configurations
        2. 6.3.1.2 Multiplexer With Minimum Crosstalk
        3. 6.3.1.3 Early Switching for Direct Sensor Interface
      2. 6.3.2 Reference
      3. 6.3.3 REFby2 Buffer
      4. 6.3.4 Converter Module
        1. 6.3.4.1 Internal Oscillator
        2. 6.3.4.2 ADC Transfer Function
      5. 6.3.5 Low-Dropout Regulator (LDO)
    4. 6.4 Device Functional Modes
      1. 6.4.1 Channel Selection Using Internal Multiplexer
        1. 6.4.1.1 Manual Mode
        2. 6.4.1.2 On-The-Fly Mode
        3. 6.4.1.3 Auto Sequence Mode
        4. 6.4.1.4 Custom Channel Sequencing Mode
      2. 6.4.2 Digital Window Comparator
    5. 6.5 Programming
      1. 6.5.1 Data Transfer Protocols
        1. 6.5.1.1 Enhanced-SPI Interface
          1. 6.5.1.1.1 Protocols for Configuring the Device
          2. 6.5.1.1.2 Protocols for Reading From the Device
            1. 6.5.1.1.2.1 SPI Protocols With a Single SDO
            2. 6.5.1.1.2.2 SPI Protocols With Dual SDO
            3. 6.5.1.1.2.3 Clock Re-Timer Data Transfer
              1. 6.5.1.1.2.3.1 Output Bus Width Options
      2. 6.5.2 Register Read/Write Operation
  8. Register Maps
    1. 7.1 Interface and Hardware Configuration Registers
      1. 7.1.1 REG_ACCESS Register (address = 00h) [reset = 00h]
      2. 7.1.2 PD_CNTL Register (address = 04h) [reset = 00h]
      3. 7.1.3 SDI_CNTL Register (address = 008h) [reset = 00h]
      4. 7.1.4 SDO_CNTL1 Register (address = 0Ch) [reset = 00h]
      5. 7.1.5 SDO_CNTL2 Register (address = 0Dh) [reset = 00h]
      6. 7.1.6 SDO_CNTL3 Register (address = 0Eh) [reset = 00h]
      7. 7.1.7 SDO_CNTL4 Register (address = 0Fh) [reset = 00h]
      8. 7.1.8 DATA_CNTL Register (address = 10h) [reset = 00h]
      9. 7.1.9 PARITY_CNTL Register (address = 11h) [reset = 00h]
    2. 7.2 Device Calibration Registers
      1. 7.2.1 OFST_CAL Register (address = 18h) [reset = 00h]
      2. 7.2.2 REF_MRG1 Register (address = 19h) [reset = 00h]
      3. 7.2.3 REF_MRG2 Register (address = 1Ah) [reset = 00h]
      4. 7.2.4 REFby2_MRG Register (address = 1Bh) [reset = 00h]
    3. 7.3 Analog Input Configuration Registers
      1. 7.3.1 AIN_CFG Register (address = 24h) [reset = 00h]
      2. 7.3.2 COM_CFG Register (address = 27h) [reset = 00h]
    4. 7.4 Channel Sequence Configuration Registers Map
      1. 7.4.1 DEVICE_CFG Register (address = 1Ch) [reset = 00h]
      2. 7.4.2 CHANNEL_ID Register (address = 1Dh) [reset = 00h]
      3. 7.4.3 SEQ_START Register (address = 1Eh) [reset = 00h]
      4. 7.4.4 SEQ_ABORT Register (address = 1Fh) [reset = 00h]
      5. 7.4.5 ON_THE_FLY_CFG Register (address = 2Ah) [reset = 00h]
      6. 7.4.6 AUTO_SEQ_CFG1 Register (address = 80h) [reset = 00h]
      7. 7.4.7 AUTO_SEQ_CFG2 Register (address = 82h) [reset = 00h]
      8. 7.4.8 Custom Channel Sequencing Mode Registers
        1. 7.4.8.1 CCS_START_INDEX Register (address = 88h) [reset = 00h]
        2. 7.4.8.2 CCS_END_INDEX Register (address = 89h) [reset = 00h]
        3. 7.4.8.3 CCS_SEQ_LOOP Register (address = 8Ah) [reset = 00h]
        4. 7.4.8.4 CCS_CHID_INDEX_m Registers (address = 8C, 8E, 90, 92, 94, 96, 98, 9A, 9C, 9E, A0, A2, A4, A6, A8, and AAh) [reset = 00h]
        5. 7.4.8.5 REPEAT_INDEX_m Registers (address = 8D, 8F, 91, 93, 95, 97, 99, 9B, 9D, 9F, A1, A3, A5, A7, A9, and ABh) [reset = 00h]
    5. 7.5 Digital Window Comparator Configuration Registers Map
      1. 7.5.1  ALERT_CFG Register (address = 2Eh) [reset = 00h]
      2. 7.5.2  HI_TRIG_AINx[15:0] Register (address = 4Dh to 30h) [reset = 0000h]
      3. 7.5.3  LO_TRIG_AINx[15:0] Register (address = 71h to 54h) [reset = 0000h]
      4. 7.5.4  HYSTERESIS_AINx[7:0] Register (address = 4Fh to 33h) [reset = 00h]
      5. 7.5.5  ALERT_LO_STATUS Register (address = 78h) [reset = 00h]
      6. 7.5.6  ALERT_HI_STATUS Register (address = 79h) [reset = 00h]
      7. 7.5.7  ALERT_STATUS Register (address = 7Ah) [reset = 00h]
      8. 7.5.8  CURR_ALERT_LO_STATUS Register (address = 7Ch) [reset = 00h]
      9. 7.5.9  CURR_ALERT_HI_STATUS Register (address = 7Dh) [reset = 00h]
      10. 7.5.10 CURR_ALERT_STATUS Register (address = 7Eh) [reset = 00h]
  9. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Multiplexer Input Connection
    2. 8.2 Typical Applications
      1. 8.2.1 1MSPS DAQ Circuit With Lowest Distortion and Noise Performance
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
        3. 8.2.1.3 Application Curve
    3.     Power Supply Recommendations
    4. 8.3 Layout
      1. 8.3.1 Layout Guidelines
        1. 8.3.1.1 Analog Signal Path
        2. 8.3.1.2 Grounding and PCB Stack-Up
        3. 8.3.1.3 Decoupling of Power Supplies
        4. 8.3.1.4 Reference Decoupling
        5. 8.3.1.5 Reference Buffer Decoupling
        6. 8.3.1.6 Multiplexer Input Decoupling
        7. 8.3.1.7 ADC Input Decoupling
        8. 8.3.1.8 Example Schematic
      2. 8.3.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 接收文档更新通知
    3. 9.3 支持资源
    4. 9.4 Trademarks
    5. 9.5 静电放电警告
    6. 9.6 术语表
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

On-The-Fly Mode

There is a latency of one cycle when switching channels using the register access, just as in manual mode. The newly selected channel data are available two cycles after selecting the desired channel. The ADS816x supports on-the-fly switching of the analog input channels of the multiplexer. Enable this mode by programming the SEQ_MODE[1:0] bits to 01b in the DEVICE_CFG register. When enabled, the analog input channel for the next conversion is determined by the first five bits sent over SDI. The desired analog input channel is selected by setting the MSB to 1 and the following four bits as the channel ID. If the MSB is 0 then the SDI bitstream is decoded as a normal frame on the rising edge of CS. Table 6-3 lists the channel selection commands for this mode.

Table 6-3 On-the-Fly Mode Channel Selection Commands
SDI BITS [15:11] SDI BITS [10:0] DESCRIPTION
1 0000 Don't care Select analog input 0
1 0001 Don't care Select analog input 1
1 0010 Don't care Select analog input 2
1 0011 Don't care Select analog input 3
1 0100 Don't care Select analog input 4
1 0101 Don't care Select analog input 5
1 0110 Don't care Select analog input 6
1 0111 Don't care Select analog input 7
1 1000 to 1 1111 Don't care Error bit is set; select analog input 0

To set the device in on-the-fly mode, configure EN_ON_THE_FLY to 1b in the ON_THE_FLY_CFG register as shown in Figure 6-13 using a 3-byte register access. When in this mode, use the 16-bit data transfer to reduce the required clock speed for operating at full throughput.

ADS8166 ADS8167 ADS8168 On-the-Fly Mode With No MUX
                    Channel Selection Latency Figure 6-13 On-the-Fly Mode With No MUX Channel Selection Latency