SBASB15 October   2024 AMC0380D-Q1

ADVANCE INFORMATION  

  1.   1
  2. Features
  3. Applications
  4. Description
  5.   Device Comparison Table
  6. Pin Configuration and Functions
  7. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Power Ratings
    6. 5.6  Insulation Specifications
    7. 5.7  Safety-Related Certifications
    8. 5.8  Safety Limiting Values
    9. 5.9  Electrical Characteristics
    10. 5.10 Switching Characteristics
    11. 5.11 Timing Diagram
  8. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Analog Input
      2. 6.3.2 Isolation Channel Signal Transmission
      3. 6.3.3 Analog Output
    4. 6.4 Device Functional Modes
  9. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Best Design Practices
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  10. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  11. Revision History
  12. 10Mechanical, Packaging, and Orderable Information
    1. 10.1 Mechanical Data

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • DFX|15
散热焊盘机械数据 (封装 | 引脚)
订购信息

Device Functional Modes

The AMC0380D-Q1 operates in one of the following states:

  • OFF-state: The low-side supply (VDD2) is below the VDD2UV threshold. The device is not responsive. OUTP and OUTN are in Hi-Z state. Internally, OUTP and OUTN are clamped to VDD2 and GND2 by ESD protection diodes.
  • Missing high-side supply: The low-side of the device (VDD2) is supplied and within the Recommended Operating Conditions section. The high-side supply (VDD1) is below the VDD1UV threshold. The device outputs the VFAILSAFE voltage.
  • Analog input overrange (positive fullscale input): VDD1 and VDD2 are within recommended operating conditions but the analog input voltage VIN is above the maximum clipping voltage VClipping, MAX. The device outputs positive VCLIPout.
  • Analog input underrange (negative fullscale input): VDD1 and VDD2 are within recommended operating conditions but the analog input voltage VIN is below the minimum clipping voltage VClipping, MIN. The device outputs negative VCLIPout.
  • Normal operation: VDD1, VDD2, and VIN are within the recommended operating conditions. The device outputs a differential voltage that is proportional to the input voltage.

Table 6-1 lists the operating modes.

Table 6-1 Device Operational Modes
OPERATING CONDITION VDD1 VDD2 VIN DEVICE
RESPONSE
OFF Don't care VDD2 < VDD2UV Don't care OUTP and OUTN are in Hi-Z state. Internally, OUTP and OUTN are clamped to VDD2 and GND2 by ESD protection diodes.
Missing high-side supply VDD1 < VDD1UV Valid(1) Don't care The device outputs the VFAILSAFE voltage.
Input overrange Valid(1) Valid(1) VIN > VClipping, MAX The device outputs positive VCLIPout.
Input underrange Valid(1) Valid(1) VIN < VClipping, MIN The device outputs negative VCLIPout.
Normal operation Valid(1) Valid(1) Valid(1) The device outputs a differential voltage that is proportional to the input voltage.