ZHCSR80A June 2009 – January 2023 AMC6821-Q1
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
TEMPERATURE MEASUREMENT | ||||||
Local sensor accuracy | TA = 0°C to 90°C | ±0.5 | ±3 | °C | ||
TA = –25°C to 100°C | ±1 | ±4 | °C | |||
Remote sensor accuracy(1) | TR = 50°C to 100°C | ±0.5 | ±3 | °C | ||
TR = –40°C to 125°C | ±1 | ±4 | °C | |||
Sensor resolution | Both channels | 0.125 | °C | |||
Conversion time | Two channels | 62.5 | ms | |||
PWM CONTROLLER | ||||||
PWM frequency range (programmable)(2) | 10 | 40k | Hz | |||
PWM frequency accuracy | TA = 25°C to 100°C | –6% | 7% | |||
Duty cycle(2) | Programmable | 0% | 100% | |||
Duty cycle resolution | 8-bit | 0.39 | %/bit | |||
FAN RPM-TO-DIGITAL CONVERTER | ||||||
Accuracy | TA = 25°C to 100°C | –6% | 7% | |||
Full-scale count(2) | 65535 | |||||
Nominal input RPM(2) | 100 | 23000 | RPM | |||
Internal clock frequency for RPM measurement | 100 | kHz | ||||
DIGITAL INPUT/OUTPUT | ||||||
VOL | Open-drain output low voltage | Sink current 6 mA, VDD = 3 V | 0 | 0.4 | V | |
IOH | Open-drain high-level output leakage current | 0.1 | 1 | μA | ||
VIH | Input high voltage | 2.1 | V | |||
VIL | Input low voltage | 0.8 | V | |||
IIH | Input high current | –1 | μA | |||
IIL | Input low current | 1 | μA | |||
Input capacitance | 5 | pF | ||||
POWER SUPPLY | ||||||
Current | VDD = 5 | 1.1 | 2 | mA | ||
Power dissipation | 5 | mW |