ZHCSBL6D september 2013 – april 2023 BQ24296 , BQ24297
PRODUCTION DATA
The device charges the battery in three phases: preconditioning, constant current and constant voltage. At the beginning of a charging cycle, the device checks the battery voltage and applies current.
VBAT | CHARGING CURRENT | REG DEFAULT SETTING | REG08[5:4] |
---|---|---|---|
VBAT < VSHORT (Typical 2 V) | 100 mA | – | 01 |
VSHORT ≤ VBAT < VBATLOWV (Typical 2 V ≤ VBAT < 3 V) | REG03[7:4] | 256 mA | 01 |
VBAT ≥ VBATLOWV (Typical VBAT ≥ 3 V) | REG02[7:2] | 2048 mA | 10 |
If the charger device is in DPM regulation or thermal regulation during charging, the actual charging current will be less than the programmed value. In this case, termination is temporarily disabled and the charging safety timer is counted at half the clock rate.