ZHCSKO6B July 2010 – January 2020 BQ24650
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
OPERATING CONDITIONS | ||||||
VVCC_OP | VCC input voltage operating range | 5 | 28 | V | ||
QUIESCENT CURRENTS | ||||||
IBAT | Total battery discharge current (sum of currents into VCC, BTST, PH, SRP, SRN, VFB), VFB ≤ 2.1V | VCC < VBAT, VCC > VUVLO (SLEEP) | 15 | µA | ||
Battery discharge current (sum of currents into BTST, PH, SRP, SRN, VFB), VFB ≤ 2.1V | VCC > VBAT, VCC > VUVLO, CE = LOW | 5 | µA | |||
VCC > VBAT, VCC > VVCCLOWV,
CE = HIGH, Charge done |
5 | µA | ||||
IAC | Adapter supply current (sum of current into VCC pin) | VCC > VBAT, VCC > VUVLO, CE = LOW | 0.7 | 1 | mA | |
VCC > VBAT, VCC > VVCCLOWV,
CE = HIGH, charge done |
2 | 3 | mA | |||
VCC > VBAT, VCC > VVCCLOWV,
CE = HIGH, Charging, Qg_total = 10 nC [1] |
25 | mA | ||||
CHARGE VOLTAGE REGULATION | ||||||
VREG | Feedback regulation voltage | 2.1 | V | |||
Charge voltage regulation accuracy | TJ = 0°C to 85°C | –0.5% | 0.5% | |||
TJ = –40°C to 125°C | –0.7% | 0.7% | ||||
IVFB | Leakage current into VFB pin | VFB = 2.1 V | 100 | nA | ||
CURRENT REGULATION – FAST CHARGE | ||||||
VIREG_CHG | SRP-SRN current sense voltage range | VIREG_CHG = VSRP – VSRN | 40 | mV | ||
Charge current regulation accuracy | VIREG_CHG = 40 mV | –3% | 3% | |||
CURRENT REGULATION – PRE-CHARGE | ||||||
VPRECHG | Precharge current sense voltage range | VIREG_PRCHG = VSRP – VSRN | 4 | mV | ||
Precharge current regulation accuracy | VIREG_PRECH = 4 mV | –25% | 25% | |||
CHARGE TERMINATION | ||||||
VTERMCHG | Termination current sense voltage range | VITERM = VSRP – VSRN | 4 | mV | ||
Termination current accuracy | VITERM = 4 mV | –25% | 25% | |||
Deglitch time for termination (both edges) | 100 | ms | ||||
tQUAL | Termination qualification time | VBAT > VRECH and ICHG < ITERM | 250 | ms | ||
IQUAL | Termination qualification current | Discharge current once termination is detected | 2 | mA | ||
INPUT VOLTAGE REGULATION | ||||||
VMPPSET | MPPSET regulation voltage | 1.2 | V | |||
Input voltage regulation accuracy | –0.6% | 0.6% | ||||
IMPPSET | Leakage current into MPPSET pin | VMPPSET = 7 V, TA = 0 – 85°C | 1 | µA | ||
VMPPSET_CD | MPPSET shorted to disable charge | 75 | mV | |||
VMPPSET_CE | MPPSET released to enable charge | 175 | mV | |||
INPUT UNDERVOLTAGE LOCKOUT COMPARATOR (UVLO) | ||||||
VUVLO | AC undervoltage rising threshold | Measure on VCC | 3.65 | 3.85 | 4 | V |
VUVLO_HYS | AC undervoltage hysteresis, falling | 350 | mV | |||
VCC LOWV COMPARATOR | ||||||
VVCC LOWV_fall | Falling threshold, disable charge | Measure on VCC | 4.1 | V | ||
VVCC LOWV_rise | Rising threshold, resume charge | 4.35 | V | |||
SLEEP COMPARATOR (REVERSE DISCHARGING PROTECTION) | ||||||
VSLEEP _FALL | SLEEP falling threshold | VVCC – VSRN to enter SLEEP | 40 | 100 | 150 | mV |
VSLEEP_HYS | SLEEP hysteresis | 500 | mV | |||
SLEEP rising shutdown deglitch | VCC falling below SRN | 100 | ms | |||
SLEEP falling powerup deglitch | VCC rising above SRN, Delay to exit SLEEP mode | 30 | ms | |||
BAT LOWV COMPARATOR | ||||||
VLOWV | Precharge to fast charge transition (LOWV threshold) | Measure on VFB pin | 1.54 | 1.55 | 1.56 | V |
VLOWV_HYS | LOWV hysteresis | 100 | mV | |||
LOWV rising deglitch | VFB falling below VLOWV | 25 | ms | |||
LOWV falling deglitch | VFB rising above VLOWV + VLOWV_HYS | 25 | ms | |||
RECHARGE COMPARATOR | ||||||
VRECHG | Recharge threshold (with respect to VREG) | Measure on VFB pin | 35 | 50 | 65 | mV |
Recharge rising deglitch | VFB decreasing below VRECHG | 10 | ms | |||
Recharge falling deglitch | VFB increasing above VRECHG | 10 | ms | |||
BAT OVERVOLTAGE COMPARATOR | ||||||
VOV_RISE | Overvoltage rising threshold | As percentage of VFB | 104% | |||
VOV_FALL | Overvoltage falling threshold | As percentage of VFB | 102% | |||
INPUT OVERVOLTAGE COMPARATOR (ACOV) | ||||||
VACOV | AC overvoltage rising threshold on VCC | 31 | 32 | 33 | V | |
VACOV_HYS | AC overvoltage falling hysteresis | 1 | V | |||
AC overvoltage deglitch (both edges) | Delay to changing the STAT pins | 1 | ms | |||
AC overvoltage rising deglitch | Delay to disable charge | 1 | ms | |||
AC overvoltage falling deglitch | Delay to resume charge | 20 | ms | |||
THERMAL SHUTDOWN COMPARATOR | ||||||
TSHUT | Thermal shutdown rising temperature | Temperature increasing | 145 | °C | ||
TSHUT_HYS | Thermal shutdown hysteresis | 15 | °C | |||
Thermal shutdown rising deglitch | Temperature increasing | 100 | µs | |||
Thermal shutdown falling deglitch | Temperature decreasing | 10 | ms | |||
THERMISTOR COMPARATOR | ||||||
VLTF | Cold temperature rising threshold | As percentage to VVREF | 72.5% | 73.5% | 74.5% | |
VLTF_HYS | Rising hysteresis | 0.2% | 0.4% | 0.6% | ||
VHTF | Hot temperature rising threshold | 46.7% | 47.5% | 48.3% | ||
VTCO | Cut-off temperature rising threshold | 44.3% | 45% | 45.7% | ||
Deglitch time for temperature out of range detection | VTS < VLTF, or VTS < VTCO, or
VTS < VHTF |
400 | ms | |||
Deglitch time for temperature in valid range detection | VTS > VLTF – VLTF_HYS or VTS >VTCO, or VTS > VHTF | 20 | ms | |||
CHARGE OVERCURRENT COMPARATOR (CYCLE-BY-CYCLE) | ||||||
VOC | Charge overcurrent rising threshold | Current rising, in synchronous mode measure (VSRP – VSRN) | 80 | mV | ||
CHARGE UNDERCURRENT COMPARATOR (CYCLE-BY-CYCLE) | ||||||
VISYNSET | Charge undercurrent falling threshold | Switch from CCM to DCM, VSRP > 2.2V | 1 | 5 | 9 | mV |
BATTERY-SHORTED COMPARATOR (BATSHORT) | ||||||
VBATSHT | BAT short falling threshold, forced non-synchronous mode | VSRP falling | 2 | V | ||
VBATSHT_HYS | BAT short rising hysteresis | 200 | mV | |||
tBATSHT_DEG | Deglitch on both edges | 1 | µs | |||
LOW CHARGE CURRENT COMPARATOR | ||||||
VLC | Low charge current falling threshold | Measure V(SRP-SRN) | 1.25 | mV | ||
VLC_HYS | Low charge current rising hysteresis | 1.25 | mV | |||
tLC_DEG | Deglitch on both edges | 1 | µs | |||
VREF REGULATOR | ||||||
VVREF_REG | VREF regulator voltage | VVCC > VUVLO, 0 – 35 mA load | 3.267 | 3.3 | 3.333 | V |
IVREF_LIM | VREF current limit | VVREF = 0 V, VVCC > VUVLO | 35 | mA | ||
REGN REGULATOR | ||||||
VREGN_REG | REGN regulator voltage | VVCC > 10 V, MPPSET > 175 mV | 5.7 | 6.0 | 6.3 | V |
IREGN_LIM | REGN current limit | VREGN = 0 V, VVCC > VUVLO, MPPSET < 75 mV | 40 | mA | ||
BATTERY DETECTION | ||||||
tWAKE | Wake timer | Max time charge is enabled | 500 | ms | ||
IWAKE | Wake current | RSENSE = 10 mΩ | 50 | 125 | 200 | mA |
tDISCHARGE | Discharge timer | Max time discharge current is applied | 1 | sec | ||
IDISCHARGE | Discharge current | 6 | mA | |||
IFAULT | Fault current after a timeout fault | 2 | mA | |||
IQUAL | Termination qualification current | 2 | mA | |||
tQUAL | Termination qualification time | 250 | ms | |||
VWAKE | Wake threshold (with respect to VREG) | Voltage on VFB to detect battery absent during wake | 50 | mV | ||
VDISCH | Discharge threshold | Voltage on VFB to detect battery absent during discharge | 1.55 | V | ||
PWM HIGH-SIDE DRIVER (HIDRV) | ||||||
RDS_HI_ON | High-side driver (HSD) turnon resistance | VBTST – VPH = 5.5 V | 3.3 | 6 | Ω | |
RDS_HI_OFF | High-side driver turnoff resistance | 1 | 1.4 | Ω | ||
VBTST_REFRESH | Bootstrap refresh comparator threshold Voltage | VBTST – VPH when low side refresh pulse is requested | 4.0 | 4.2 | V | |
PWM LOW-SIDE DRIVER (LODRV) | ||||||
RDS_LO_ON | Low-side driver (LSD) turn-on resistance | 4.1 | 7 | Ω | ||
RDS_LO_OFF | Low-side driver turn-off resistance | 1 | 1.4 | Ω | ||
PWM DRIVERS TIMING | ||||||
Driver dead-time | Dead time when switching between LSD and HSD, No load at LSD and HSD | 30 | ns | |||
PWM OSCILLATOR | ||||||
VRAMP_HEIGHT | PWM ramp height | As percentage of VCC | 7% | |||
PWM switching frequency | 510 | 600 | 690 | kHz | ||
INTERNAL SOFT START (8 STEPS TO REGULATION CURRENT ICHG) | ||||||
Soft-start steps | 8 | step | ||||
Soft-start step time | 1.6 | ms | ||||
CHARGER SECTION POWER-UP SEQUENCING | ||||||
Charge-enable delay after power-up | Delay from MPPSET > 175 mV to charger is allowed to turn on | 1.5 | s | |||
LOGIC IO PIN CHARACTERISTICS (STAT1, STAT2, TERM_EN) | ||||||
VOUT_LOW | STAT1, STAT2 output low saturation voltage | Sink current = 5 mA | 0.5 | V | ||
IOUT_HI | Leakage current | V = 32 V | 1.2 | µA | ||
VIN_LOW | TERM_EN input low threshold voltage | 0.4 | V | |||
VIN_HI | TERM_EN input high threshold voltage | 1.6 | V | |||
IIN_BIAS | TERM_EN bias current | VTERM_EN = 0.5 V | 60 | µA |