ZHCSKO6B July 2010 – January 2020 BQ24650
PRODUCTION DATA.
Battery current is sensed by resistor RSR connected between SRP and SRN. The full-scale differential voltage between SRP and SRN is fixed at 40 mV. Thus, for a 20-mΩ sense resistor, the charging current is 2 A. For charging current, refer to Equation 3: