VIN_OV |
Update VIN_OV status, Update STAT to fault, interrupt on INT, PG shown not good |
Disabled |
Enabled through BAT |
Enabled through BAT |
Disabled |
VIN_UV |
Update VIN_UV status, Update STAT to fault, interrupt on INT, PG shown not good |
Disabled |
Enabled through BAT |
Enabled through BAT |
Disabled |
VIN_ILIM |
Update charge in progress status, interrupt on INT, input current is limited |
Enabled, input current limited |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled |
OVER_TEMP |
|
Disabled |
Disabled |
Disabled |
Disabled |
BAT_UVLO |
Update BAT_UVLO status, Update STAT to fault, interrupt on INT |
Pre-charge |
Enabled (if enabled) and VIN Valid |
Enabled (if enabled) and VIN Valid |
Enabled if VIN Valid |
SW_SYS_SHORT |
|
Enabled |
Current Limit |
Enabled (if enabled) |
Enabled |
LS_LDO_OCP |
|
Enabled |
Enabled (if enabled) |
Current Limit |
Enabled |
TIMER fault |
Update TIMER, Update STAT to fault, interrupt on INT |
Disabled |
Enabled (if enabled) |
Enabled (if enabled) |
Disabled |
VINDPM |
Update VINDPM_STAT, Update STAT to fault, interrupt on INT |
Enabled, input current reduced |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled |
TS_FAULT COLD or HOT |
Update TS_FAULT to COLD OR HOT, Update STAT to fault, interrupt on INT |
Disabled |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled |
TS_FAULT COOL |
Update TS_FAULT to COOL, Update STAT to fault, interrupt on INT |
Reduce ICHG to ½ |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled |
TS_FAULT WARM |
Update TS_FAULT to WARM, Update STAT to fault, interrupt on INT |
Reduce VBATREG by 140 mV |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled |
Charge Done |
Update STAT to Charge Done, interrupt on INT |
Disabled, monitor for VBAT falling below VRCHG |
Enabled (if enabled) |
Enabled (if enabled) |
Enabled
|