ZHCSSA7 october 2020 BQ25302
PRODUCTION DATA
The device operates in different modes depending on VBUS voltage, battery voltage, and EN pin, POL pin, and ICHG pin connection. The functional modes are listed in the following table.
MODE | CONDITIONS | REGN LDO | CHARGE ENABLED | STAT PIN |
---|---|---|---|---|
Disable Mode | Device is disable | OFF | NO | OPEN |
HiZ Mode | VVBUS < VVBUS_UVLOZ and device is enabled | OFF | NO | OPEN |
Sleep Mode | VVBUS > VVBUS_UVLOZ and VVBUS < VBAT + VSLEEPZ and device is enabled | OFF | NO | OPEN |
Charge Mode | VVBUS > VVBUS_LOWV and VVBUS > VBAT + VSLEEPZ and device is enabled, no faults, charge is not terminated | ON | YES | SHORT to GND |
Charge Termination Mode | VVBUS > VVBUS_LOWV and VVBUS > VBAT + VSLEEPZ and device is enabled, no faults, charge is terminated | ON | NO | OPEN |
Fault Mode | VBUS_OVP, TS cold/hot, VBAT_OVP, IC thermal shutdown, safety timer fault, ICHG pin open or short | ON | NO | BLINKING |