4 修订历史记录
Changes from F Revision (December 2018) to G Revision
- Changed From: "330 mV typical,.." To: "600 mV typical,.." in the second paragraph of the Overview sectionGo
- Changed Figure 21Go
- Changed From: "VIN(CS) = 330 mV typical." To: "VIN(CS) = 600 mV typical." in the last paragraph of the Cold-Start Operation sectionGo
Changes from E Revision (March 2015) to F Revision
- 将特性从“冷启动电压:VIN ≥ 330mV(典型)”更改为“冷启动电压:VIN ≥ 600mV”Go
- Changed the RGR Package appearanceGo
- Increased VIN(CS) From: TYP = 330 mV and MAX = 450 mV To: TYP = 600 mV and MAX = 700 mV in Electrical Characteristics tableGo
Changes from D Revision (December 2014) to E Revision
- Changed the Test Condition for PIN(CS) in the Electrical CharacteristicsGo
- Changed the values for PIN(CS) in the Electrical Characteristics From: TYP = 5 To: TYP = 15Go
- Changed CBYP = 0.1 µF To: CBYP = 0.01 µF in Detailed Design ProcedureGo
- Changed CBYP = 0.1 µF To: CBYP = 0.01 µF in Detailed Design ProcedureGo
- Changed CBYP = 0.1 µF To: CBYP = 0.01 µF in Detailed Design ProcedureGo
Changes from C Revision (December 2013) to D Revision
- Added 添加了 ESD 额定值 表、特性 说明部分,器件功能模式,应用和实施部分,电源相关建议部分,布局部分,器件和文档支持部分以及机械、封装和可订购信息部分Go
Changes from B Revision (September 2013) to C Revision
- Go
- 将特性从:效率高达 98% 改为:效率高达 93%Go
- 将 说明 部分的文本从“继续收集低至 VIN = 120mV 的能量。” 更改为“继续收集低至 VIN = 100mV 的能量。”Go
- Changed Peak Input Power n the Absolute Maximum Ratings table From: MAX = 400 mW To: MAX = 510 mWGo
- Changed VIN(DC) in the Recommended Operating Conditions table From: MIN = 0.12 V MAX = 4 V To: MIN = 0.1 V MAX = 5.1 VGo
- Changed VIN(DC) in the Electrical Characteristics table From: MIN = 120 mV MAX = 4000 mV To: MIN = 100 mV MAX = 5100 mVGo
- Changed PIN in the Electrical Characteristics table From: MAX = 400 mW To: MAX = 510 mWGo
- Added VDELTA, VBAT_OV - VIN(DC to the ELECTRICAL CHARACTERISTICS tableGo
- Changed VOUT_EN(H) From: VSTOR - 0.2 To: VSTOR - 0.4 in the ELECTRICAL CHARACTERISTICS tableGo
Changes from A Revision (September 2013) to B Revision
- Changed values in the Thermal Information tableGo
Changes from * Revision (March 2013) to A Revision
- Changed the data sheet from a Product Brief to Production dataGo