ZHCSKP6A January 2020 – February 2022 BQ25616
PRODUCTION DATA
When battery charging is enabled (CE pin is LOW), the device autonomously completes a charging cycle. The device default charging parameters are listed in Table 9-4.
DEFAULT MODE | BQ25616/616J |
---|---|
Charging voltage | VSET pin, 4.10 V/4.20 V/4.35 V |
Charging current | ICHG pin |
Pre-charge current | 5% of ICHG |
Termination current | 5% of ICHG |
Temperature profile | JEITA (BQ25616J), Hot/Cold (BQ25616) |
Safety timer | 10 hours |
A new charge cycle starts when the following conditions are valid:
The device automatically terminates the charging cycle when the charging current is below the termination threshold, the battery voltage is above the recharge threshold, and the device is not in DPM mode or thermal regulation. When a fully charged battery is discharged below recharge threshold, the device automatically starts a new charging cycle. After the charge is done, a toggle of the CE pin initiates a new charging cycle. Adapter removal and replug will also restart a charging cycle.
The STAT output indicates charging status: charging (LOW), charging complete or charge disable (HIGH), or charging fault (blinking).