The charger employs a synchronous
buck converter that allows charging the 1s to 4s battery from an input power source.
With a battery attached at BAT and input power at VBUS, the charger can provide
at least the MINSYS voltage at SYS and charge current for the battery at BAT.
Once the battery voltage reaches the MINSYS voltage, the SYS voltage follows the
BAT voltage up. With no battery attached to BAT and input power at VBUS, the
voltages at SYS and BAT vary depending on the whether or not charge is enabled
as explained below.
- No battery or battery removed and
charge disabled by CE pin or EN_CHG register or thermistor removed from TS pin -
The charger keeps the BAT pin voltage at low-level, steady-state voltage and
regulates SYS pin to MINSYS. The host can monitor the ADC BAT pin voltage and TS
fault register to determine when a valid battery is attached.
- No battery or battery removed
while charge enabled and TS pin function is disabled - The charger continuously
tries to charge the BAT capacitance, typically resulting in the BAT voltage
alternating between a low level and BATOVP fault. The SYS voltage follows the
battery voltage up, potentially reaching SYSOVP fault. In order to determine if
a battery is attached, the host must periodically disable charge, force IBAT
discharge current and then read the ADC BAT pin voltage. Alternatively, the host
can monitor the INT pin for rapid interrupts and then read the charge status
bits for fast (<1 s for typical BAT pin capacitance) toggling between
charging, taper and termination.