ZHCSO21 may   2021 BQ25720

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Description (continued)
  7. Device Comparison Table
  8. Pin Configuration and Functions
  9. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  10. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Power-Up Sequence
      2. 9.3.2  Vmin Active Protection (VAP) with Battery only
      3. 9.3.3  Two-Level Battery Discharge Current Limit
      4. 9.3.4  Fast Role Swap Feature
      5. 9.3.5  CHRG_OK Indicator
      6. 9.3.6  Input and Charge Current Sensing
      7. 9.3.7  Input Voltage and Current Limit Setup
      8. 9.3.8  Battery Cell Configuration
      9. 9.3.9  Device HIZ State
      10. 9.3.10 USB On-The-Go (OTG)
      11. 9.3.11 Converter Operation
      12. 9.3.12 Inductance Detection Through IADPT Pin
      13. 9.3.13 Converter Compensation
      14. 9.3.14 Continuous Conduction Mode (CCM)
      15. 9.3.15 Pulse Frequency Modulation (PFM)
      16. 9.3.16 Switching Frequency and Dithering Feature
      17. 9.3.17 Current and Power Monitor
        1. 9.3.17.1 High-Accuracy Current Sense Amplifier (IADPT and IBAT)
        2. 9.3.17.2 High-Accuracy Power Sense Amplifier (PSYS)
      18. 9.3.18 Input Source Dynamic Power Management
      19. 9.3.19 Input Current Optimizer (ICO)
      20. 9.3.20 Two-Level Adapter Current Limit (Peak Power Mode)
      21. 9.3.21 Processor Hot Indication
        1. 9.3.21.1 PROCHOT During Low Power Mode
        2. 9.3.21.2 PROCHOT Status
      22. 9.3.22 Device Protection
        1. 9.3.22.1 Watchdog Timer
        2. 9.3.22.2 Input Overvoltage Protection (ACOV)
        3. 9.3.22.3 Input Overcurrent Protection (ACOC)
        4. 9.3.22.4 System Overvoltage Protection (SYSOVP)
        5. 9.3.22.5 Battery Overvoltage Protection (BATOVP)
        6. 9.3.22.6 Battery Discharge Overcurrent Protection (BATOC)
        7. 9.3.22.7 Battery Short Protection (BATSP)
        8. 9.3.22.8 System Undervoltage Lockout (VSYS_UVP) and Hiccup Mode
        9. 9.3.22.9 Thermal Shutdown (TSHUT)
    4. 9.4 Device Functional Modes
      1. 9.4.1 Forward Mode
        1. 9.4.1.1 System Voltage Regulation with Narrow VDC Architecture
        2. 9.4.1.2 Battery Charging
      2. 9.4.2 USB On-The-Go
      3. 9.4.3 Pass Through Mode (PTM)-Patented Technology
    5. 9.5 Programming
      1. 9.5.1 SMBus Interface
        1. 9.5.1.1 SMBus Write-Word and Read-Word Protocols
        2. 9.5.1.2 Timing Diagrams
    6. 9.6 Register Map
      1. 9.6.1  ChargeOption0 Register (SMBus address = 12h) [reset = E70Eh]
      2. 9.6.2  ChargeCurrent Register (SMBus address = 14h) [reset = 0000h]
        1. 9.6.2.1 Battery Pre-Charge Current Clamp
      3. 9.6.3  ChargeVoltage Register (SMBus address = 15h) [reset value based on CELL_BATPRESZ pin setting]
      4. 9.6.4  ChargerStatus Register (SMBus address = 20h) [reset = 0000h]
      5. 9.6.5  ProchotStatus Register (SMBus address = 21h) [reset = B800h]
      6. 9.6.6  IIN_DPM Register With 10-mΩ Sense Resistor (SMBus address = 22h) [reset = 4100h]
      7. 9.6.7  ADCVBUS/PSYS Register (SMBus address = 23h)
      8. 9.6.8  ADCIBAT Register (SMBus address = 24h)
      9. 9.6.9  ADCIINCMPIN Register (SMBus address = 25h)
      10. 9.6.10 ADCVSYSVBAT Register (SMBus address = 26h)
      11. 9.6.11 ChargeOption1 Register (SMBus address = 30h) [reset = 3300h]
      12. 9.6.12 ChargeOption2 Register (SMBus address = 31h) [reset = 00B7]
      13. 9.6.13 ChargeOption3 Register (SMBus address = 32h) [reset = 0434h]
      14. 9.6.14 ProchotOption0 Register (SMBus address = 33h) [reset = 4A81h(2S~) 4A09(1S)]
      15. 9.6.15 ProchotOption1 Register (SMBus address = 34h) [reset = 41A0h]
      16. 9.6.16 ADCOption Register (SMBus address = 35h) [reset = 2000h]
      17. 9.6.17 ChargeOption4 Register (SMBus address = 36h) [reset = 0048h]
      18. 9.6.18 Vmin Active Protection Register (SMBus address = 37h) [reset = 006Ch(2s~4s)/0004h(1s)]
      19. 9.6.19 OTGVoltage Register (SMBus address = 3Bh) [reset = 09C4h]
      20. 9.6.20 OTGCurrent Register (SMBus address = 3Ch) [reset = 3C00h]
      21. 9.6.21 InputVoltage (VINDPM) Register (SMBus address = 3Dh) [reset = VBUS-1.28V]
      22. 9.6.22 VSYS_MIN Register (SMBus address = 3Eh) [reset value based on CELL_BATPRESZ pin setting]
      23. 9.6.23 IIN_HOST Register (SMBus address = 3Fh) [reset = 4100h]
      24. 9.6.24 ID Registers
        1. 9.6.24.1 ManufactureID Register (SMBus address = FEh) [reset = 0040h]
        2. 9.6.24.2 Device ID (DeviceAddress) Register (SMBus address = FFh) [reset = 00E1h]
  11. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 ACP-ACN Input Filter
        2. 10.2.2.2 Inductor Selection
        3. 10.2.2.3 Input Capacitor
        4. 10.2.2.4 Output Capacitor
        5. 10.2.2.5 Power MOSFETs Selection
      3. 10.2.3 Application Curves
  12. 11Power Supply Recommendations
  13. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
      1. 12.2.1 Layout Example Reference Top View
      2. 12.2.2 Inner Layer Layout and Routing Example
  14. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 第三方米6体育平台手机版_好二三四免责声明
    2. 13.2 Documentation Support
      1. 13.2.1 Related Documentation
    3. 13.3 接收文档更新通知
    4. 13.4 支持资源
    5. 13.5 Trademarks
    6. 13.6 静电放电警告
    7. 13.7 术语表
  15. 14Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Two-Level Adapter Current Limit (Peak Power Mode)

Usually adapter can supply current higher than DC rating for a few milliseconds to tens of milliseconds. The charger employs two-level input current limit, or peak power mode, to fully utilize the overloading capability and minimize battery discharge during system load transient. The level 1 current limit, or ILIM1, is the same as adapter DC current, set in IIN_DPM register. The level 2 overloading current, or ILIM2, is set in ILIM2_VTH, as a percentage of ILIM1.

When the charger detects input current surge and battery discharge due to load transient (both the adapter and battery support the system together), or when the charger detects the system voltage starts to drop below VSYS_MIN setting due to load transient (only the adapter supports the system), the charger will first apply ILIM2 for TOVLD (PKPWR_TOVLD_DEG register bits), and then ILIM1 for up to TMAX – TOVLD time. TMAX is programmed in PKPWR_TMAX register bits. After TMAX, if the load is still high, another peak power cycle starts. Charging is disabled during TMAX and TOVLD already expires; once TMAX, expires, a new cycle starts and resumes charging automatically.

To prepare entering peak power follow below steps:

  • Set EN_IIN_DPM=1b to enable input current dynamic power management.
  • Set EN_EXTILIM=0b to disable external current limit.
  • Set register IIN_HOST based on adapter output current rating as the level 1 current limit(ILIM1)
  • Set register bits ILIM2_VTH according to the adapter overload capability as the level 2 current limit(ILIM2) .
  • Set register bits PKPWR_TOVLD_DEG as ILIM2 effective duration time for each peak power mode operation cycle based on adapter capability.
  • Set register bits PKPWR_TMAX as each peak power mode operation cycling time based on adapter capability.

Depends on the battery existence and charge status peak power mode can be finally enabled with two different approaches:

  • When battery is depleted in which VBAT is lower than VSYS_MIN setting or battery is removed, host need to set EN_PKPWR_VSYS=1b to enable peak power mode triggered by system voltage undershoot. The under-shoot threshold is the VSYS_MIN register setting which is the system regulation point before load transient happens. Typical application waveform refer to Figure 10-21.
  • When battery is not depleted in which VBAT is higher than VSYS_MIN setting, host need to set EN_PKPWR_IIN_DPM=1b to enable peak power mode triggered by input current overshoot. The overshoot threshold is IIN_DPM register which is same as the level 1 current limit (ILIM1). Typical application waveform refer to Figure 10-22.

GUID-20200930-CA0I-CPGG-5JZV-P0BJRPWH3PJD-low.svg Figure 9-3 Two-Level Adapter Current Limit Timing Diagram