ZHCSJ56C February 2018 – September 2019 BQ25882
PRODUCTION DATA.
The battery over-voltage limit is clamped at 4% above the battery regulation voltage while charging. When battery overvoltage occurs, the charger device immediately disables charge. The fault register BATOVP_STAT bit goes high and an INT pulse is asserted to signal the host.