ZHCSJI9A March 2019 – June 2019 BQ25886
PRODUCTION DATA.
When battery charging is enabled (CE pin is LOW), the device autonomously completes a charging cycle without host involvement. The device default charging parameters are listed in Table 5 below.
DEFAULT MODE | BQ25886 |
---|---|
Charging Voltage | Set by VSET |
Charging Current | Set by ICHGSET |
Pre-Charge Current | 1/10 of ICHG |
Termination Current | 1/10 of ICHG |
Temperature Profile | JEITA |
Safety Timer | 12 hours |
A new charge cycle starts when the following conditions are valid:
The charger automatically terminates the charging cycle when the charging current is below termination threshold, charge voltage is above recharge threshold, and device is not in DPM mode or thermal regulation. When a full battery voltage is discharged below recharge threshold (threshold fixed at 200 mV for BQ25886), the device automatically starts a new charging cycle. After the charge is done, toggle CE pin can initiate a new charging cycle.