While many of the default parameters
in the data flash are suitable for most applications, the following should first be
reviewed and modified to match the intended application.
- Design Capacity:
Enter the value in mAh divided by
CurrScale()
for the battery, even from the “design energy” point of
view.
- Design Energy:
Enter the value in cWh divided by
EnergyScale().
- Cell Charge Voltage
Tx-Ty: Enter the desired cell charge voltage for each JEITA
temperature range.