ZHCSF78E June 2016 – April 2019 BQ35100
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
ICC_ACCU(1) | Gas gauge in ACCUMULATOR mode | GE = High AND GaugeStart() received and GaugeStop() not Received (GMSEL1,0 = 0,0) | 130 | µA | ||
ICC_SOH(1) | State-of-health operating current | GE = High AND GaugeStart() received and GaugeStop() not Received (GMSEL1,0 = 0,1) | 40 | µA | ||
ICC_EOS_Burst(1) | End-of-service operating current—data burst | GE = High AND GaugeStart() received and GaugeStop() not Received (GMSEL1,0 = 1,0) | 315 | µA | ||
ICC_EOS_Gather(1) | End-of-service operating current—data gathering | GE = High AND GaugeStart() AND GaugeStop() Received (GMSEL1,0 = 1,0) | 75 | µA | ||
ICC_GELOW(1) | Device Disabled | GE = LOW | 0.05 | µA |