ZHCSF78E June 2016 – April 2019 BQ35100
PRODUCTION DATA.
For optimal accuracy, the first event where the device updates its impedance value is required to be when the battery is full (a fresh battery). If the battery is partially discharged, then the accuracy of the EOS detection is compromised.
When a new battery is inserted, then the NEW_BATTERY() command should be sent to the device to ensure the initial learned resistance RNEW is refreshed correctly.