The WPC allows for a special command for the receiver to terminate power transfer from the transmitter termed End Power Transfer (EPT) packet. Table 5 specifies the v1.2 reasons column and their corresponding data field value. The condition column corresponds to the methodology used by bq51003 to send equivalent message.
MESSAGE | VALUE | CONDITION |
---|---|---|
Unknown | 0x00 | TS-CTRL = 1, or ,EN1 EN2> = <10> or AD > VAD_EN |
Charge Complete | 0x01 | <EN1 EN2> = <11> |
Internal Fault | 0x02 | TJ > 150°C or RILIM < 100 Ω |
Over Temperature | 0x03 | TS < VHOT, TS > VCOLD, or TS-CTRL < 100 mV |
Over Voltage | 0x04 | Not Sent |
Over Current | 0x05 | NOT USED |
Battery Failure | 0x06 | Not Sent |
Reconfigure | 0x07 | Not Sent |
No Response | 0x08 | VRECT target does not converge |