ZHCSJM7 April 2019 BQ79606A-Q1
PRODUCTION DATA.
The BAT input must include a low-pass filter using a 0.33-μF capacitor and a 100Ω resistor to avoid voltage stress during cell connection (hot-plug). Figure 41 illustrates the correct VBAT connection. If voltage spikes greater than 36V are expected, connect a transient suppression diode (TVS) to TOP to clamp the voltage to below 36 V to prevent an over-voltage condition on BAT during these events.