TA = 25°C, VBAT = 3.6 V PARAMETER | TEST
CONDITIONS(1)(2) | MIN | TYP | MAX | UNIT |
---|
TX | 6 OFDM | | 318 | | mA |
54 OFDM | | 293 | |
RX(3) | 54 OFDM | | 61 | | mA |
Idle connected(4) | | | 690 | | µA |
LPDS | | | 115 | | µA |
Hibernate | | | 5.5 | | µA |
Shutdown | | | 1 | | µA |
Peak calibration
current(5)(3) | VBAT = 3.6 V | | 290 | | mA |
VBAT = 3.3 V | | 310 | |
VBAT = 2.7 V | | 310 | |
VBAT = 2.3 V | | 365 | |
(1) TX power level = 0 implies maximum power (see
Figure 8-1,
Figure 8-2, and
Figure 8-3). TX power level = 4 implies output power backed off approximately 4 dB.
(2) The CC3135MOD system is a constant power-source system. The active current numbers scale based on the VBAT voltage supplied.
(3) The RX current is measured with a 1-Mbps throughput rate.
(4) DTIM = 1
(5) The complete calibration can take up to 17 mJ of energy from the battery over a time of 24 ms. In default mode, calibration is performed sparingly, and typically occurs when re-enabling the NWP and when the temperature has changed by more than 20°C. There are two additional calibration modes that may be used to reduced or completely eliminate the calibration event. For further details, see
CC31XX, CC32XX SimpleLink™ Wi-Fi® and IoT Network Processor Programmer's Guide.