ZHCSQ72D November   1997  – March 2022 CD54HC4024 , CD54HCT4024 , CD74HC4024 , CD74HCT4024

PRODUCTION DATA  

  1. 特性
  2. 说明
  3. Revision History
  4. Pin Configuration and Functions
  5. Specifications
    1. 5.1 Absolute Maximum Ratings (1)
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Prerequisite for Switching Specifications
    6. 5.6 Switching Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  8. Power Supply Recommendations
  9. Layout
    1. 9.1 Layout Guidelines
  10. 10Device and Documentation Support
    1. 10.1 接收文档更新通知
    2. 10.2 支持资源
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • D|14
  • PW|14
  • N|14
散热焊盘机械数据 (封装 | 引脚)
订购信息

Switching Characteristics

tr, tf = 6 ns. See (Parameter Measurement Information)
PARAMETER TEST CONDITIONS VCC (V) 25℃ -40℃ to 85℃ -55℃ to 125℃ UNIT
MIN TYP MAX MIN MAX MIN MAX
HC TYPES
tPLH, tPHL Propagation delay time


CP to Q1' output

CL = 50 pF 2 140 175 210 ns
4.5 28 35 42 ns
CL = 15 pF 5 11 ns
CL = 50 pF 6 24 30 36 ns
tPLH, tPHL Propagation delay time,

Qn to Qn + 1

CL = 50 pF 2 75 95 110 ns
4.5 15 19 22 ns
CL = 15 pF 5 6 ns
CL = 50 pF 6 13 13 19 ns
tPLH, tPHL Propagation delay time,

MR to Qn

CL = 50 pF 2 170 215 255 ns
4.5 34 43 51 ns
5 14 ns
6 29 27 43 ns
tTLH, tTHL Output transition time CL = 50 pF 2 75 95 110 ns
4.5 15 19 22 ns
6 13 16 19 ns
CIN Input capacitance CL = 50 pF 10 10 10 pF
CPD Power dissipation capacitance(1)(2) CL = 15 pF 5 30 pF
HCT TYPES
tPLH, tPHL Propagation delay time


CP to Q1' output

CL = 50 pF 4.5 40 50 60 ns
ns
CL = 15 pF 5 17 ns
ns
tPLH, tPHL Propagation delay time,

Qn to Qn + 1

CL = 50 pF 4.5 15 19 22 ns
CL = 15 pF 5 6 ns
tPLH, tPHL Propagation delay time,

MR to Qn

CL = 50 pF 4.5 40 50 60
CL = 15 pF 5 17
tTLH, tTHL Output transition time CL = 50 pF 4.5 15 19 22 ns
CIN Input capacitance CL = 15 pF 10 10 10 pF
CPD Power dissipation capacitance(1)(2) CL = 15 pF 5 30 pF
CPD is used to determine the dynamic power consumption, per buffer.
PD = VCC2 fi + Σ (CL VCC2 fi/M) where: M = 21, 22, 23, 24, 25, 26, 27 fi = input frequency, CL = output load capacitance, VCC = supply voltage.