ZHCSFZ0D December 2016 – December 2023 DAC38RF80 , DAC38RF83 , DAC38RF84 , DAC38RF85 , DAC38RF90 , DAC38RF93
PRODUCTION DATA
Valid SYSREF frequencies depend on the following parameters:
Maximum SYSREF frequency = (Sample clock frequency/N),
where N =LCM(CLKJESD_DIV,4 x K x F). N is the Least common multiple of 4 x K x F and CLKJESD_DIV.
All valid SYSREF frequencies are integer divisors of the maximum SYSREF frequency.
Example:
Given sampling clock frequency = 8.84736 GSPS, Interpolation = 24, DAC Mode=L-M-F-S=8-8-2-1 and K=20:
CLKJESD_DIV = 24 (CLKJESD_DIV)
Maximum SYSREF Frequency = 8847.36 MHz/240 = 36.864 MHz
Valid SYSREF Frequencies = 36.864 MHz/n, where n is any positive integer.