PARAMETER |
TEST CONDITIONS |
MIN |
NOM |
MAX |
UNIT |
Micromirror tilt angle |
DMD landed state(1) |
|
12 |
|
degree |
Micromirror tilt angle tolerance(2) |
|
–1 |
|
1 |
degree |
(1) Measured relative to the plane formed by the overall micromirror array at 25°C.
(2) For some applications, it is critical to account for the micromirror tilt angle variation in the overall optical system design. With some optical system designs, the micromirror tilt angle variation within a device may result in perceivable non-uniformities in the light field reflected from the micromirror array. With some optical system designs, the micromirror tilt angle variation between devices may result in colorimetry variations, system efficiency variations, or system contrast variations.