During power-down, VCC and VCCI must be supplied until after VBIAS, VRESET, and VOFFSET are discharged to within the specified limit of ground. See Table 9-1.
During power-down, it is a strict requirement
that the voltage delta between VBIAS and VOFFSET must be within the specified
limit shown in Section 6.4.
During power-down, there is no requirement for the relative timing of VRESET with respect to VBIAS.
Power supply slew rates during power-down are
flexible, provided that the transient voltage
levels follow the requirements specified in Section 6.1,
in
Section 6.4,
and in Figure 9-1.
During power-down, LVCMOS input pins must be less
than specified in Section 6.4.
B. To prevent excess current, the supply
voltage delta |VCCI – VCC| must be less than specified limit in Section 6.4.
C. To prevent excess current, the supply
voltage delta |VBIAS – VOFFSET| must be less than specified in Section 6.4.
D. To prevent excess current, the supply
voltage delta |VBIAS – VRESET| must be less than specified limit in Section 6.4.
E. VBIAS must power up
after VOFFSET has powered up, per the Delay1
specification in Table 9-1.
F. PG_OFFSET must turn
off after EN_OFFSET has turned off, per the Delay2
specification in Table 9-1.
G. DLP controller
software enables the DMD power supplies to turn on
after RESET_OEZ is at logic high.
H. DLP controller
software initiates the global VBIAS
command.
I. After the DMD
micromirror park sequence is complete, the DLP
controller software initiates a hardware
power-down that activates PWRDNZ and disables
VBIAS, VRESET and VOFFSET.
J. Under power-loss conditions where
emergency DMD micromirror park procedures are being enacted by the DLP controller
hardware, EN_OFFSET may turn off after PG_OFFSET has turned off. The RESET_OEZ
signal goes high prior to PG_OFFSET turning off to indicate the DMD micromirror has
completed the emergency park procedures.
Table 9-1 DMD Power-Supply Requirements
Parameter
Description
Min
NOM
Max
Unit
Delay1
Delay from VOFFSET settled at recommended operating voltage to VBIAS power up