ZHCSIC7H March 2016 – November 2019 DRA722 , DRA724 , DRA725 , DRA726
PRODUCTION DATA.
Adaptive Voltage Scaling (AVS) and Adaptive Body Biasing (ABB) are required on most of the vdd_* supplies as defined in Table 5-6.
Supply | AVS Required? | ABB Required? |
---|---|---|
vdd_core | Yes, for all OPPs | No |
vdd_mpu | Yes, for all OPPs | Yes, for all OPPs |
vdd_iva | Yes, for all OPPs | Yes, for all OPPs |
vdd_dsp | Yes, for all OPPs | Yes, for all OPPs |
vdd_gpu | Yes, for all OPPs | Yes, for all OPPs |
vdd_rtc | No | No |