ZHCSII2E August 2016 – May 2019 DRA790 , DRA791 , DRA793 , DRA797
PRODUCTION DATA.
Adaptive Voltage Scaling (AVS) and Adaptive Body Biasing (ABB) are required on most of the vdd_* supplies as defined in Table 5-2.
SUPPLY | VOLTAGE DOMAIN | AVS REQUIRED? | ABB REQUIRED? |
---|---|---|---|
vdd | VD_CORE | Yes, for all OPPs | No |
VD_SGX | Yes, for all OPPs | Yes, for all OPPs | |
VD_MPU | Yes, for all OPPs | Yes, for all OPPs | |
vdd_dsp | VD_DSP | Yes, for all OPPs | Yes, for all OPPs |
VD_IVA | Yes, for all OPPs | Yes, for all OPPs |