ZHCSN40K February 2019 – April 2024 DRA829J , DRA829J-Q1 , DRA829V , DRA829V-Q1
PRODUCTION DATA
Tables and figures provided in this section define switching characteristics for MCU_SAFETY_ERRORn and SOC_SAFETY_ERRORn.
NO. | PARAMETER | MIN | MAX | UNIT | |
---|---|---|---|---|---|
SFTY1 | tw(MCU_SAFETY_ERRORn) | Pulse width minimum,
MCU_SAFETY_ERRORn active (PWM mode disabled) |
P*R(1)(2) | ns | |
SFTY2 | td (ERROR_CONDITION-MCU_SAFETY_ERRORnL) | Delay time, ERROR CONDITION to
MCU_SAFETY_ERRORn active |
50*P(1) | ns |
NO. | PARAMETER | MIN | MAX | UNIT | |
---|---|---|---|---|---|
SFTY3 | tw(SOC_SAFETY_ERRORn) | Pulse width
minimum,SOC_SAFETY_ERRORn active (PWM mode disabled) |
P*R(1)(2) | ns | |
SFTY4 | td (ERROR_CONDITION-SOC_SAFETY_ERRORnL) | Delay time, ERROR CONDITION to
SOC_SAFETY_ERRORn active |
50*P(1) | ns |