ZHCSDF4F May 2014 – March 2018 DRV2604L
PRODUCTION DATA.
The DRV2604L has multiple modes for playing waveforms, as well as a calibration mode and a diagnostic mode. Table 1 lists the available modes.
MODE | MODE[2:0] | N_PWM_ANALOG |
---|---|---|
Internal trigger mode | 0 | X |
External Trigger mode (edge) | 1 | X |
External trigger mode (level) | 2 | X |
Analog input mode | 3 | 0 |
PWM mode | 3 | 1 |
RTP mode | 5 | X |
Diagnostics mode | 6 | X |
Calibration mode | 7 | X |