SLVSH22 May 2024 DRV8000-Q1
ADVANCE INFORMATION
NAME | CONDITION | SPI BIT | MODE | DIGITAL CORE | CHARGE PUMP | DRIVERS | CURRENT SENSE | RESPONSE |
---|---|---|---|---|---|---|---|---|
Disable Gate Driver | DRVOFF = High or EN_GD = 0b |
n/a | n/a | Active | Active | Pull Down | Active | n/a |
SPI Clock Fault | Invalid SPI Clock Frame | SCLK_FLT | Latched | Active | Active | Active | Active | SPI_ERR, SPI, Reject Frame |
DVDD Power-on-Reset | DVDD < VDVDD_POR | POR | n/a | Reset | Disabled | Semi-Active Pull Down | Disabled | SPI |
PVDD Undervoltage | PVDD < VPVDD_UV | PVDD_UV | Latched | Active | Disabled | Semi-Active Pull Down | Disabled | SPI |
Automatic | Active | Disabled | Semi-Active Pull Down | Disabled | SPI | |||
PVDD Overvoltage | PVDD > VPVDD_OV | PVDD_OV | Latched | Active | Active | Pull Down | Active | SPI |
PVDD_OV | Automatic | Active | Active | Pull Down | Active | SPI | ||
PVDD_OV | Warning | Active | Active | Active | Active | WARN, SPI | ||
n/a | Disabled | Active | Active | Active | Active | n/a | ||
VCP Undervoltage | VCP < VVCP_UV | VCP_UV | Latched | Active | Disabled | Semi-Active Pull Down | Disabled | SPI |
Automatic | Active | Active | Semi-Active Pull Down | Disabled | SPI | |||
VDS Overcurrent | VDS > VVDS_LVL | GD, VDS_X | Latched | Active | Active | IVDS_IDRVN Pull Down |
Active | SPI |
Cycle | Active | Active | IVDS_IDRVN Pull Down |
Active | SPI | |||
Warning | Active | Active | Active | Active | WARN, SPI | |||
Disabled | Active | Active | Active | Active | n/a | |||
VGS Gate Fault | VGS > VVGS_LVL | GD, VGS_X | Latched | Active | Active | Pull Down | Active | SPI |
Cycle | Active | Active | Pull Down | Active | SPI | |||
Warning | Active | Active | Active | Active | WARN, SPI | |||
Disabled | Active | Active | Active | Active | n/a | |||
Offline Open Load | n/a | VDS_X | MCU | Active | Active | Pull Down | Active | SPI |
Offline Short Circuit | n/a | VDS_X | MCU | Active | Active | Pull Down | Active | SPI |
Half-bridge Overcurrent Fault (OUT1-OUT6) | IOUTx > IOCPx | HB, OUTx_HS_OCP, OUTx_LS_OCP | Latched | Active | Active | Affected driver Hi-Z | Active | SPI |
Half-bridge active open load Fault (OUT1-OUT6) | IOUTx < IOLP_OUTx | HB, OUTx_OLA | Latched | Active | Active | Active | Active | WARN |
Half-bridge passive open load Fault (OUT1-OUT6) | IOUTx < IOLP_OUTx | HB, HB_OLP_STAT | Live | Active | Active | n/a | Active | WARN |
High-side Driver overcurrent Fault (OUT7-OUT12) | IOUTx > IOCPx | HS, OUTx_OCP | Latched | Active | Active | Affected driver Hi-Z | Active | SPI |
High-side Driver OUT7 ITRIP | IOUT7 > IOC7 | ITRIP, OUT7_ITRIP_STAT | Warning | Active | Active | n/a | Active | WARN |
tOUT7_ITRIP > tOUT7_ITRIP_TO | HS, ITRIP, OUT7_ITRIP_TO, OUT7_ITRIP_STAT | Latched | Active | Active | OUT7 Hi-Z after timeout | Active | SPI | |
IOUT7 > IOC7 | ITRIP, OUT7_ITRIP_STAT | Warning | Active | Active | OUT7 ITRIP regulation indefinite | Active | WARN | |
tOUT7_ITRIP > tOUT7_ITRIP_TO | ITRIP, OUT7_ITRIP_TO, OUT7_ITRIP_STAT | Warning | Active | Active | OUT7 ITRIP regulation disabled; | Active | WARN | |
High-side Driver open load Fault (OUT7-OUT12) | IOUTx < IOCPx | HS, OUTx_OLP | Warning | Active | Active | Active | Active | WARN |
ECFB Overvoltage | VECFB>VECFB_OV | EC_HEAT, ECFB_OV | Disabled | Active | Active | n/a | Active | n/a |
VECFB>VECFB_OV | EC_HEAT, ECFB_OV | Latched | Active | Active | n/a | Active | SPI | |
VECFB>VECFB_OV | EC_HEAT, ECFB_OV | Latched | Active | Active | ECDRV pulled down, ECFB LS FET Hi-Z | Active | SPI | |
ECFB Undervoltage | VECFB>VECFB_UV | EC_HEAT, ECFB_UV | Disabled | Active | Active | n/a | Active | n/a |
VECFB>VECFB_UV | EC_HEAT, ECFB_UV | Latched | Active | Active | n/a | Active | SPI | |
VECFB>VECFB_UV | EC_HEAT, ECFB_UV | Latched | Active | Active | ECDRV pulled down, ECFB LS FET Hi-Z | Active | SPI | |
ECFB Above Target Voltage | VECFB>VEC_V_TAR | EC_HEAT, ECFB_HI | Live | Active | Active | n/a | Active | WARN |
ECFB Below Target Voltage | VECFB<VEC_V_TAR | EC_HEAT, ECFB_LO | Live | Active | Active | n/a | Active | WARN |
ECFB Overcurrent (discharge) | IECFB> IECFB_OC | EC_HEAT, ECFB_OC | Latched | Active | Active | ECFB Hi-Z | Active | SPI |
ECFB Open load (discharge) | IECFB< IOL_ECFB_LS | EC_HEAT, ECFB_OL | Latched | Active | Active | n/a | Active | WARN, SPI |
ECFB Open load (active/charge, OUT11 independent mode, ECDRV_OL_EN enabled) | VECFB> VECFB_OV | EC_HEAT, ECFB_OL, ECFB_OV | Latched | Active | Active | n/a | Active | WARN, SPI |
Heater VDS Overcurrent Fault | VHEAT_VDS > VHEAT_VDS_LVL | EC_HEAT, HEAT_VDS | Latched | Active | Active | Pull down | Active | SPI |
Cycle | Active | Active | Pull Down | Active | SPI | |||
Warning | Active | Active | Active | Active | WARN, SPI | |||
Disabled | Active | Active | Active | Active | n/a | |||
Heater VDS Open load Fault | VSH_HS > VOL_HEAT | EC_HEAT, HEAT_OL | Latched | Active | Active | Pull down | Active | SPI |
Zone X Thermal Warning | TJ > TOTW_X | OTW, ZONEx_OTW_X | Automatic | Active | Active | Active | Active | WARN, SPI |
Zone X Thermal Shutdown | TJ > TOTSD | OTSD, ZONEx_OTSD | Latched | Active | Disabled | Semi-Active Pull Down, Hi-Z | Disabled | SPI |
Watchdog | Invalid Access or Expiration | WD_FLT | Warning | Active | Active | Active | Active | WARN, SPI |
Latched Fault | Active | Active | Pull Down | Active | SPI |