ZHCSRD7B January 2023 – March 2024 DRV8145-Q1
PRODUCTION DATA
参数 | 测试条件 | 最小值 | 典型值 | 最大值 | 单位 | |
---|---|---|---|---|---|---|
SRHSON | 输出电压上升时间,10% - 90% | SR = 3'b000 或 LVL2 | 1.7 | V/µs | ||
SR = 3'b001(仅 SPI) | 4.4 | V/µs | ||||
SR = 3'b010(仅 SPI) | 6.1 | V/µs | ||||
SR = 3'b011 或 LVL3 | 10.8 | V/µs | ||||
SR = 3'b100 或 LVL4 | 17.2 | V/µs | ||||
SR = 3'b101 或 LVL1 | 23.2 | V/µs | ||||
SR = 3'b110 或 LVL6 | 34.1 | V/µs | ||||
SR = 3'b111 或 LVL5 | 43.8 | V/µs | ||||
tPD_HSON | 输出电压上升期间的传播时间 | SR = 3'b000 或 LVL2 | 4.3 | µs | ||
SR = 3'b001(仅 SPI) | 2.2 | µs | ||||
SR = 3'b010(仅 SPI) | 1.6 | µs | ||||
SR = 3'b011 或 LVL3 | 1.3 | µs | ||||
所有其他 SR | 1.1 | µs | ||||
tDEAD_HSON | 输出电压上升期间的死区时间 | SR = 3'b000 或 LVL2 | 3.5 | µs | ||
SR = 3'b001(仅 SPI) | 5.2 | µs | ||||
SR = 3'b010(仅 SPI) | 1 | µs | ||||
所有其他 SR | 0.5 | µs | ||||
SRHSOFF | 输出电压下降时间,90% - 10% | SR = 3'b000 或 LVL2 | 2 | V/µs | ||
SR = 3'b001(仅 SPI) | 5.4 | V/µs | ||||
SR = 3'b010(仅 SPI) | 10.4 | V/µs | ||||
SR = 3'b011 或 LVL3 | 15.1 | V/µs | ||||
SR = 3'b100 或 LVL4 | 21.2 | V/µs | ||||
SR = 3'b101 或 LVL1 | 27.1 | V/µs | ||||
SR = 3'b110 或 LVL6 | 38.5 | V/µs | ||||
SR = 3'b111 或 LVL5 | 48.5 | V/µs | ||||
tPD_HSOFF | 输出电压下降期间的传播时间 | 所有 SR | 0.3 | µs | ||
tDEAD_HSOFF | 输出电压下降期间的死区时间 | 所有 SR | 0.23 | µs | ||
tBLANK | 输出转换后的电流调节消隐时间使电流感测稳定(仅对 LS 再循环有效) | SR = 3'b000 或 LVL2 | 10.8 | µs | ||
SR = 3'b001 或 3'b010(仅 SPI) | 3.6 | µs | ||||
所有其他 SR | 2.7 | µs |