The OLON bit can assume the following values:
0b = no Open Load at ON state detected, or the channel is OFF when the diagnosis is performed
1b = Open Load at ON state detected
According to the setting of EN_OLON, different information are reported in the Standard Diagnosis.
EN_OLON set to 0010b to 0111b : The OLON bit shows the Open Load at ON state diagnosis performed on the selected channel. The information is updated at every Standard Diagnosis readout.
EN_OLON set to 1010b : the OLON bit shows the OR combination of all bits in OLONx register. The information is updated while the diagnosis loop is running.
EN_OLON set to 1111b : the OLON bit shows the result of the latest diagnosis loop performed. It is necessary to start another diagnosis loop to update the information.
EN_OLON set to any other value: The OLON bit is set to 0b. These values of EN_OLON bits are reserved and should not be used in the application.