ZHCSHZ0A April 2018 – July 2018 DRV8306
PRODUCTION DATA.
The DRV8306 device is fully protected against VM undervoltage, charge pump undervoltage, MOSFET VDS overcurrent, gate driver shorts, and overtemperature events.
FAULT | CONDITION | REPORT | GATE DRIVER | LOGIC | RECOVERY |
---|---|---|---|---|---|
VM undervoltage
(UVLO) |
VVM < VUVLO | nFAULT | Hi-Z | Disabled | Automatic:
VVM > VUVLO |
Charge pump undervoltage
(CPUV) |
VVCP < VCPUV | nFAULT | Hi-Z | Active | Automatic:
VVCP > VCPUV |
VDS overcurrent
(VDS_OCP) |
VDS > VVDS_OCP | nFAULT | Hi-Z | Active | Retry:
tRETRY |
VSENSE overcurrent
(SEN_OCP) |
VSP > VSEN_OCP | nFAULT | Hi-Z | Active | Retry:
tRETRY |
Gate driver fault
(GDF) |
Gate voltage stuck > tDRIVE | nFAULT | Hi-Z | Active | Latched:
ENABLE Pulse |
Thermal shutdown
(OTSD) |
TJ > TOTSD | nFAULT | Hi-Z | Active | Automatic:
TJ < TOTSD – THYS |