The GVDD charge pump provides a regulated voltage
on GVDD pin. The GVDD is a power supply source of bootstrap diode
and also VCP Trickle charge pump.
Note: Setting DIS_GVDD_SS to 1b is recommended after power up. In case
DIS_GVDD_SS remains 0b, the GVDD output load capability may not meet the test limits
of electrical characteristic table when PVDD input voltage is lower than 7.2V.