ZHCSR67 July 2020 DRV8353M
PRODUCTION DATA
FAULT | CONDITION | CONFIGURATION | REPORT | GATE DRIVER | RECOVERY |
---|---|---|---|---|---|
VM Undervoltage (VM_UV) | VVM < VVM_UV | — | nFAULT | Hi-Z | Automatic: VVM > VVM_UV |
VDRAIN Undervoltage (VDR_UV) | VVDRAIN < VVDR_UV | — | nFAULT | Hi-Z | Automatic: VVM > VVDR_UV |
Charge Pump Undervoltage (VCP_UV) | VVCP < VVCP_UV | DIS_GDUV = 0b | nFAULT | Hi-Z | Automatic: VVCP > VVCP_UV |
DIS_GDUV = 1b | None | Active | |||
VGLS Regulator Undervoltage (VGLS_UV) | VVGLS < VVGLS_UV | DIS_GDUV = 0b | nFAULT | Hi-Z | Automatic: VVGLS > VVGLS_UV |
DIS_GDUV = 1b | None | Active | |||
VDS Overcurrent (VDS_OCP) | VDS > VVDS_OCP | OCP_MODE = 00b | nFAULT | Hi-Z | Latched: CLR_FLT, ENABLE Pulse |
OCP_MODE = 01b | nFAULT | Hi-Z | Retry: tRETRY | ||
OCP_MODE = 10b | nFAULT | Active | No action | ||
OCP_MODE = 11b | None | Active | No action | ||
VSENSE Overcurrent (SEN_OCP) | VSP > VSEN_OCP | OCP_MODE = 00b | nFAULT | Hi-Z | Latched: CLR_FLT, ENABLE Pulse |
OCP_MODE = 01b | nFAULT | Hi-Z | Retry: tRETRY | ||
OCP_MODE = 10b | nFAULT | Active | No action | ||
OCP_MODE = 11b or DIS_SEN = 1b | None | Active | No action | ||
Gate Driver Fault (GDF) | VGS Stuck > tDRIVE | DIS_GDF = 0b | nFAULT | Hi-Z | Latched: CLR_FLT, ENABLE Pulse |
DIS_GDF = 1b | None | Active | No action | ||
Thermal Warning (OTW) | TJ > TOTW | OTW_REP = 1b | nFAULT | Active | Automatic: TJ < TOTW – THYS |
OTW_REP = 0b | None | Active | No action | ||
Thermal Shutdown (OTSD) | TJ > TOTSD | — | nFAULT | Hi-Z | Automatic: TJ < TOTSD – THYS |