CPL |
1 |
27 |
PWR |
Charge pump output |
Connect a VM rated, 0.1-µF ceramic capacitor between CPH and CPL |
CPH |
2 |
28 |
VCP |
3 |
1 |
O |
Charge pump output |
Connect a 16-V, 0.47-µF ceramic capacitor to VM |
VM |
4, 11 |
2, 9 |
PWR |
Power supply |
Connect to motor supply voltage; bypass to GND with two 0.1 µF (for each pin) plus one bulk capacitor rated for VM |
AOUT1 |
5 |
3 |
O |
Winding A output |
H-bridge outputs, drives one winding of a stepper motor |
AOUT2 |
7 |
5 |
AISEN |
6 |
4 |
O |
Winding A sense |
Requires sense resistor to GND; value sets peak current in winding A |
BOUT2 |
8 |
6 |
O |
Winding B output |
H-bridge outputs, drives one winding of a stepper motor |
BOUT1 |
10 |
8 |
BISEN |
9 |
7 |
O |
Winding B sense |
Requires sense resistor to GND; value sets peak current in winding B |
GND |
12, 28 |
10, 26 |
PWR |
Device ground |
Must be connected to ground |
AVREF |
13 |
11 |
I |
Reference voltage input |
Voltage on this pin sets the full scale chopping current in H-bridge A |
BVREF |
14 |
12 |
Voltage on this pin sets the full scale chopping current in H-bridge B |
V3P3 |
15 |
13 |
— |
Internal regulator |
Internal supply voltage; bypass to GND with a 6.3-V, 0.47-µF ceramic capacitor; up to 10-mA external load |
TOFF |
16 |
14 |
I |
Decay mode off time set |
Sets the off-time during current chopping; tri-level pin |
nSLEEP |
17 |
15 |
I |
Sleep mode input |
Logic high to enable device; logic low to enter low-power sleep mode; internal pulldown |
nFAULT |
18 |
16 |
O |
Fault indication pin |
Pulled logic low with fault condition; open-drain output requires an external pullup |
BDECAY |
19 |
17 |
I |
Decay mode setting pins |
Set the decay mode for bridge B; see Decay Modes; tri-level pin |
ADECAY |
20 |
18 |
Set the decay mode for bridge A; see Decay Modes; tri-level pin |
TRQ1 |
26 |
24 |
I |
Torque DAC current scalar |
Scales the current by 100%, 75%, 50%, or 25%; internal pulldown |
TRQ0 |
27 |
25 |
PAD |
PAD |
PAD |
PWR |
Thermal pad |
Must be connected to ground |