7.1 Absolute Maximum Ratings(1)(2)(3)
|
MIN |
MAX |
UNIT |
Supply voltage (VDD - 2.5-V mode) |
–0.5 |
2.75 |
V |
Supply voltage (VIN - 3.3-V mode) |
–0.5 |
4 |
V |
LVCMOS Input/Output Voltage |
–0.5 |
4 |
V |
CML input voltage |
–0.5 |
VDD + 0.5 |
V |
CML input current |
–30 |
30 |
mA |
Junction temperature |
|
125 |
°C |
Lead temperature soldering (4 sec.) |
|
260 |
°C |
Storage temperature, Tstg |
–40 |
125 |
°C |
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or other conditions beyond those indicated in the
Recommended Operating Conditions is not implied. The Recommended Operating Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions. Absolute Maximum Numbers are specified for a junction temperature range of –40°C to +125°C. Models are validated to Maximum Operating Voltages only.
(3) If Military/Aerospace specified devices are required, contact the Texas Instruments Sales Office/Distributors for availability and specifications.