Follow these general
guidelines when designing the power supply:
- Design
the power supply so that it provides the DC voltage,
AC noise, and start-up ramp time outlined in the
Recommended Operating Conditions
section.
- The
DS320PR410 does not require any special power supply
filtering, such as ferrite beads, provided that the
recommended operating conditions are met. Only
standard supply decoupling is required. Typical
supply decoupling consists of a 0.1 µF capacitor per
VCC pin, one 1.0 µF bulk capacitor per device, and
one 10 µF bulk capacitor per power bus that delivers
power to one or more DS320PR410 devices. The local
decoupling (0.1 µF) capacitors must be connected as
close to the VCC pins as possible and with minimal
path to the DS320PR410 ground
pad.