Follow these general guidelines when
designing the power supply:
- The power supply should be
designed to provide the operating conditions outlined in the recommended
operating conditions section in terms of DC voltage, AC noise, and start-up
ramp time.
- The DS320PR822 does not require any special power supply filtering, such as
ferrite beads, provided that the recommended operating conditions are met.
Only standard supply decoupling is required. Typical supply decoupling
consists of a 0.1 µF capacitor per VCC pin, one 1.0 µF bulk capacitor per
device, and one 10 µF bulk capacitor per power bus that delivers power to
one or more DS320PR822 devices. The local decoupling
(0.1 µF) capacitors must be connected as close to the VCC pins as possible
and with minimal path to the DS320PR822 ground pad.
- The DS320PR822 voltage regulator output pins require decoupling caps of 0.1
µF near each pin. The regulator is only for internal use. Do not use to
provide power to any external component.