ZHCSOU1 February 2023 DS90UB638-Q1
PRODUCTION DATA
Receiver port control register assigns rules for lock and pass in the general status register and allows for enabling and disabling the Rx port.
BIT | FIELD | TYPE | DEFAULT | DESCRIPTION |
---|---|---|---|---|
7:6 | RESERVED | R | 10 | Reserved |
5:4 | PASS_SEL | RW | 00 | Pass Output Select This field controls the source of the PASS output. 00: Port 0 Receiver Pass This field can only be written via a local I2C controller. |
3:2 | LOCK_SEL | RW | 0 | Lock Output Select This field controls the source of the LOCK output. 00: Port 0 Receiver Lock This field can only be written via a local I2C controller. |
1 | RESERVED | RW | 1 | Set to 0 at start-up. This is required for proper operation. |
0 | PORT0_EN | RW | 1 | Port 0 Receiver Enable 0: Disable Port 0 Receiver 1: Enable Port 0 Receiver |