ZHCSCQ6C August 2014 – October 2024 FDC1004
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
fSCL | Clock frequency(1) | 10 | 400 | kHz | ||
tLOW | Clock low time(1) | 1.3 | µs | |||
tHIGH | Clock high time(1) | 0.6 | µs | |||
tHD;STA | Hold time (repeated) START condition(1) | After this period, the first clock pulse is generated | 0.6 | µs | ||
tSU;STA | Set-up time for a repeated START condition(1) | 0.6 | µs | |||
tHD;DAT | Data hold time(1)(2) | 0 | ns | |||
tSU;DAT | Data setup time(1) | 100 | ns | |||
tf | SDA fall time(1) | IL ≤ 3mA; CL ≤ 400pF | 300 | ns | ||
tSU;STO | Set-up time for STOP condition(1) | 0.6 | µs | |||
tBUF | Bus free time between a STOP and START condition(1) | 1.3 | µs | |||
tVD;DAT | Data valid time(1) | 0.9 | ns | |||
tVD;ACK | Data valid acknowledge time(1) | 0.9 | ns | |||
tSP | Pulse width of spikes that must be suppressed by the input filter(1) | 50 | ns |