ZHCSCQ6C August   2014  – October 2024 FDC1004

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 I2C Interface Voltage Level
    7. 5.7 I2C Interface Timing
    8. 5.8 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 The Shield
      2. 6.3.2 The CAPDAC
      3. 6.3.3 Capacitive System Offset Calibration
      4. 6.3.4 Capacitive Gain Calibration
    4. 6.4 Device Functional Modes
      1. 6.4.1 Single Ended Measurement
      2. 6.4.2 Differential Measurement
    5. 6.5 Programming
      1. 6.5.1 Serial Bus Address
      2. 6.5.2 Read/Write Operations
      3. 6.5.3 Device Usage
        1. 6.5.3.1 Measurement Configuration
        2. 6.5.3.2 Triggering Measurements
        3. 6.5.3.3 Wait for Measurement Completion
        4. 6.5.3.4 Read of Measurement Result
    6. 6.6 Register Maps
      1. 6.6.1 Registers
        1. 6.6.1.1 Capacitive Measurement Registers
        2. 6.6.1.2 Measurement Configuration Registers
        3. 6.6.1.3 FDC Configuration Register
        4. 6.6.1.4 Offset Calibration Registers
        5. 6.6.1.5 Gain Calibration Registers
        6. 6.6.1.6 Manufacturer ID Register
        7. 6.6.1.7 Device ID Register
  8. Applications and Implementation
    1. 7.1 Application Information
      1. 7.1.1 Liquid Level Sensor
      2. 7.1.2 46
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
      3. 7.2.3 Application Curve
    3. 7.3 Best Design Practices
    4. 7.4 Initialization Set Up
    5. 7.5 Power Supply Recommendations
    6. 7.6 Layout
      1. 7.6.1 Layout Guidelines
      2. 7.6.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 接收文档更新通知
    3. 8.3 支持资源
    4. 8.4 Trademarks
    5. 8.5 静电放电警告
    6. 8.6 术语表
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

I2C Interface Timing

Over recommended operating free-air temperature range, VDD = 3.3V, for TA = TJ = 25°C (unless otherwise noted).
PARAMETERTEST CONDITIONSMINTYPMAXUNIT
fSCLClock frequency(1)10400kHz
tLOWClock low time(1)1.3µs
tHIGHClock high time(1)0.6µs
tHD;STAHold time (repeated) START condition(1)After this period, the first clock pulse is generated0.6µs
tSU;STASet-up time for a repeated START condition(1)0.6µs
tHD;DATData hold time(1)(2)0ns
tSU;DATData setup time(1)100ns
tfSDA fall time(1)IL ≤ 3mA; CL ≤ 400pF300ns
tSU;STOSet-up time for STOP condition(1)0.6µs
tBUFBus free time between a STOP and START condition(1)1.3µs
tVD;DATData valid time(1)0.9ns
tVD;ACKData valid acknowledge time(1)0.9ns
tSPPulse width of spikes that must be suppressed by the input filter(1)50ns
This parameter is specified by design and/or characterization and is not tested in production.
The FDC1004 provides an internal 300ns minimum hold time to bridge the undefined region of the falling edge of SCL.
FDC1004 I2C TimingFigure 5-1 I2C Timing