9 Revision History
Changes from Revision B (April 2015) to Revision C (October 2024)
- 将数据表标题从“FDC1004 适用于电容式感应解决方案的 4 通道电容数字转换器”更改为“FDC1004 适用于电容式感应应用的 4 通道电容数字转换器”Go
- 更新了整个文档中的表格、图和交叉参考的编号格式Go
- 将提到 I2C 的旧术语实例通篇更改为控制器和目标Go
- 将器件信息 表更改为封装信息
Go
- Changed Equation 1
Go
Changes from Revision A (October 2014) to Revision B (April 2015)
- 通篇将最大温度范围从 85°C 更改为 125°CGo
- 添加了 VSSOP 封装类型Go
- Deleted WSON DAP explicit assignment to GND in diagramGo
- Added VSSOP package diagram Go
- Changed table from Handling Ratings to ESD Ratings and moved Storage Temp to Absolute Maximum Ratings Go
- Added JA thermal resistance for VSSOP package Go
- Added JC thermal resistance for WSON package Go
- Added JC thermal resistance for VSSOP package Go
- Added JC thermal resistance for WSON package Go
- Added JB thermal resistance for VSSOP package Go
- Added note to Electrical Characteristics limits Go
- Changed TcCOFF to "46" from "30"Go
- Changed GERR to "0.2" from "0.07" Go
- Changed gain error unit to "%" from "% of full scale"Go
- Changed tcG to "-37.5" from "2.1" Go
- Changed tcG unit to "ppm/°C" from "ppm of full scale/°C"Go
- Added testing for PSRR conditionGo
- Changed PSRR to "13.6" from "11" Go
- Changed FRCAPDACto "96.9" from "96.875" Go
- Deleted CAPDAC resolution from EC tableGo
- Changed TcCOFFCAPDAC to "30" from "1" Go
- Changed TcCOFFCAPDACto "fF" from "ppm of FS/°C" Go
- Changed DRV value of 400pF from typ and moved to max limitGo
- Added note to Electrical Characteristics table Go
- Changed plot for Active Supply Current vs Temperature due to change in temperature range Go
- Changed plot for Stand-by Supply Current vs Temperature due to change in temperature range Go
- Changed plot for Gain Drift vs Temperature due to change in temperature range and gain drift unit Go
- Changed plot for Offset Drift vs Temperature due to change in temperature range Go
- Added capacitance vs voltage plot Go
- Changed shield configuration example for differential mode from "CIN2-CIN1, where CHA=CIN2 and CHB=CIN1" to "CIN1-CIN2, where CHA=CIN1 and CHB=CIN2" Go
- Changed shield configuration example for differential mode from "CIN2-CIN1, where CHA=CIN2 and CHB=CIN1" to "CIN1-CIN2, where CHA=CIN1 and CHB=CIN2" Go
- Changed plot for Active Supply Current vs Temperature due to change
in temperature range Go
Changes from Revision * (August 2014) to Revision A (October 2014)
- Added Parameter not tested in production Go
- Changed CINx to CINn throughout Go
- Added note for Applications and Implementation section.Go